Break acircuit under abnormal short circuit overload condition or any other fault.
Sf6 circuit breaker maintenance ppt.
The sf 6 circuit breaker is mainly.
Since beginning the circuit breaker replacement project in 2004 itc has ge atb 7 with free standing gas ct ppj replaced or decommissioned 81 sf6 circuit breakers the cost of breaker replacement ranges from 200 000 for a 120kv breaker up tofrom 200 000 for a 120kv breaker up to 500 000 for a 345kv breaker mitsubishi 300sfmt 63e.
Circuit breaker maintenance in easy steps information supplied by megger circuit breakers cbs sit quietly for months or even years apparently doing nothing.
Applications a typical sf6 circuit breaker consists of interrupter units each capable of dealing with currents up to 60 ka and voltages in the range of 50 80 kv.
Sulphur hexafluoride sf6 gas is used as an arc quenching medium.
Sf 6 sulphur hexafluoride gas has excellent dielectric arc quenching chemical and other physical properties which have proved its superiority over other arc quenching mediums such as oil or air.
These procedures normally consist of removing the sf6 from the circuit breaker filtering and storing it in a gas cart as a liquid and transferring it back to the circuit breaker after the circuit breaker maintenance has been performed.
Eventually the time comes however when the breaker is required to operate and then it must respond instantly.
Free electron in the arc are captured by the gas.
Sf6 is an electro negative gas.
A number of units are connected in series according to the system voltage.
A circuit breaker isan equipment which can makeor break acircuit either manually or automatically under normal conditions.
This breaker uses sf6 or sulfur hexafluoride as arc quenching or arc extinguisher medium.
It has strong tendency to absorb electrons.
But like minimum oil circuit breaker the sf6 cb only utilizes the extinguishing property of the sf6 gas since this page is about the maintenance of sf6 circuit breaker let us go to the topic directly.
Sf6 has high electro negativity i e high affinity of absorbing free electron.
A circuit breaker in which thecurrent carrying contactsoperate in sulphur hexafluoridegas sf6 isknown assf6 circuit breaker.
Although sf6 has very good dielectric property.
When contact are opened in a high pressure flow of sf6 gas arc produced.
Introduction a circuit breaker in which the current carrying contacts operate m sulphur hexafluoride or sf6 gas is known as an sf6 circuit breaker.
Sf6 has excellent insulating property.
Which build up enough insulation strength to extinguish arc.
The procedures for handling nonfaulted sf6 are well covered in manufacturer s instruction books.
Outdoor power curcuit breaker.
Sf6 power tool pdf manual download.
View and download abb sf6 installation and maintenance instructions manual online.